Alimentations médicales MDS Adaptater Delta


Description


Modèle MDS-005AAS05 A MDS-005AAS05 B MDS-005AAS05 C MDS-030AAC05 MDS-030AAC12 MDS-030AAC15
Output Voltage 5V 5V 5V 5V 12V 15V
Output Power 5W 5W 5W 15W 24W 30W
Output Current 1A 1A 1A 3A 2A 2A
Input Voltage Range 90-264Vac 90-264Vac 90-264Vac 85-264Vac 85-264Vac 85-264Vac
Dimensions (L x W x D) 56.5 x 39.5 x 28 mm

2.22” x 1.56” x 1.10”
56.5 x 39.5 x 28 mm

2.22” x 1.56” x 1.10”
56.5 x 39.5 x 28 mm
2.22” x 1.56” x 1.10”
88 x 53.5 x 27.5 mm
3.46” x 2.11” x 1.08”
88 x 53.5 x 27.5 mm
3.46” x 2.11” x 1.08”
88 x 53.5 x 27.5 mm
3.46” x 2.11” x 1.08”
Highlights & Features  -Efficiency Level VI
-Class B EMI and 4th Edition Immunity Compliant
-IP22 Ingress Protection Rating
-1 Million Hours MTBF
-IT & Medical Safety Approvals
 -Meet Efficiency Level VI
-Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-IP22 Ingress Protection Rating
-1 Million Hours MTBF
 -Meet Efficiency Level VI
-Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-IP22 Ingress Protection Rating
-1 Million Hours MTBF
 -Meet Efficiency Level VI
-Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Meets Limited Power Source (LPS) requirements
-Low touch current. Suitable for type BF applications
-Detachable AC plug with multiple country options
-IP22 ingress protection rating
-2 × MOPP isolation
-500K hours MTBF
 -Meet Efficiency Level VI
-Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Meets Limited Power Source (LPS) requirements
-Low touch current. Suitable for type BF applications
-Detachable AC plug with multiple country options
-IP22 ingress protection rating
-2 × MOPP isolation
-500K hours MTBF
 -Meet Efficiency Level VI
-Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Meets Limited Power Source (LPS) requirements
-Low touch current. Suitable for type BF applications
-Detachable AC plug with multiple country options
-IP22 ingress protection rating
-2 × MOPP isolation
-500K hours MTBF
Modèle MDS-030AAC24 MDS-060AAS12 B MDS-060AAS15 B MDS-060AAS19 B MDS-060AAS24 B MDS-060BAS12 A
Output Voltage 24V 12V 15V 19V 24V 12V
Output Power 30W 60W 60W 60W 60W 60W
Output Current 1.25A 5A 4A 3.15A 2.5A 5A
Input Voltage Range 85-264Vac 90-275Vac 90-275Vac 90-275Vac 90-275Vac 90-264Vac
Dimensions (L x W x D) 88 x 53.5 x 27.5 mm
3.46” x 2.11” x 1.08”
135 x 62 x 34.1 mm
5.31” x 2.44” x 1.34”
135 x 62 x 34.1 mm
5.31” x 2.44” x 1.34”
135 x 62 x 34.1 mm
5.31” x 2.44” x 1.34”
135 x 62 x 34.1 mm
5.31” x 2.44” x 1.34”
135 x 62 x 34.1 mm
5.31” x 2.44” x 1.34”
Highlights & Features  -Meet Efficiency Level VI
-Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Meets Limited Power Source (LPS) requirements
-Low touch current. Suitable for type BF applications
-Detachable AC plug with multiple country options
-IP22 ingress protection rating
-2 × MOPP isolation
-500K hours MTBF
 -Meet DOE Level V
-Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 62368-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Low touch current (<0.1 mA Normal & <0.3 mA single fault)
-Over-Voltage/Load/Temperature & Short Circuit protections
-1 Million Hours MTBF
-2 × MOPP isolation
-3 years warranty
 -Meet Efficiency Level VI
-Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 62368-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Low touch current (<0.1 mA Normal & <0.3 mA single fault)
-Over-Voltage/Load/Temperature & Short Circuit protections
-1 Million Hours MTBF
-2 × MOPP isolation
-3 years warranty
 -Meet Efficiency Level VI
-Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 62368-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Low touch current (<0.1 mA Normal & <0.3 mA single fault)
-Over-Voltage/Load/Temperature & Short Circuit protections
-1 Million Hours MTBF
-2 × MOPP isolation
-3 years warranty
 -Meet DOE Level VI and ErP Lot 7
-Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 62368-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Low touch current (<0.1 mA Normal & <0.3 mA single fault)
-Over-Voltage/Load/Temperature & Short Circuit protections
-1 Million Hours MTBF
-2 × MOPP isolation
-3 years warranty
 -Meet Efficiency Level VI
-Safety Approvals to IEC 60601-1 3rd ed. & IEC 60950-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Low touch current (<0.1 mA Normal & <0.3 mA single fault)
-Over-Voltage/Load/Temperature & Short Circuit protections
-1 Million Hours MTBF
-2 x MOPP (means of patient protection)
-3 years warranty
Modèle MDS-060BAS19 A MDS-060BAS24 A MDS-080AAS12 A MDS-090AAS15 F/B MDS-090AAS19 F/B MDS-090AAS24 F/B
Output Voltage 19V 24V 12V 15V 19V 24V
Output Power 60W 60W 80W 90W 90W 90W
Output Current 3.15A 2.5A 6.67A 6A 4.73A 3.75A
Input Voltage Range 90-264Vac 90-264Vac 90-264Vac 90-264Vac 90-264Vac 90-264Vac
Dimensions (L x W x D) 135 x 62 x 34.1 mm
5.31” x 2.44” x 1.34”
135 x 62 x 34.1 mm
5.31” x 2.44” x 1.34”
150 x 75 x 40 mm
5.91” x 2.95” x 1.57”
150 x 65 x 35 mm
5.91” x 2.56” x 1.38”
150 x 65 x 35 mm
5.91” x 2.56” x 1.38”
150 x 65 x 35 mm
5.91” x 2.56” x 1.38”
Highlights & Features  -Meet DOE Level VI and ErP Lot 7
-Safety Approvals to IEC 60601-1 3rd ed. & IEC 60950-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Low touch current (<0.1 mA Normal & < 0.3 mA single fault)
-Over-Voltage/Load/Temperature & Short Circuit protections
-1 Million Hours MTBF
-2 x MOPP (means of patient protection)
-3 years warranty
 -Meet DOE Level V and ErP Lot 7
-Safety Approvals to IEC 60601-1 3rd ed. & IEC 60950-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Low touch current (<0.1 mA Normal & <0.3 mA single fault)
-Over-Voltage/Load/Temperature & Short Circuit protections
-1 Million Hours MTBF
-2 x MOPP (means of patient protection)
-3 years warranty
 -Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 62368-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Low touch current (<0.1mA Normal & ,0.3mA single fault)
-Over-Voltage/Load/Temperature & Short Circuit protections
-1 Million Hours MTBF
-2 × MOPP isolation
-3 years warranty
 -Meet Efficiency Level VI
-Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 62368-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Low touch current (<0.1mA Normal & <0.3mA single fault)
-Over-Voltage/Load/Temperature & Short Circuit protections
-1 Million Hours MTBF
-2 × MOPP isolation
-3 years warranty
 -Meet DOE Level VI and ErP Lot 7
-Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 62368-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Low touch current (<0.1mA Normal & <0.3mA single fault)
-Over-Voltage/Load/Temperature & Short Circuit protections
-1 Million Hours MTBF
-2 × MOPP isolation
-3 years warranty
 -Meet DOE Level VI and ErP Lot 7
-Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 62368-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Low touch current (<0.1mA Normal & <0.3mA single fault)
-Over-Voltage/Load/Temperature & Short Circuit protections
-1 Million Hours MTBF
-2 × MOPP isolation
-3 years warranty
Modèle MDS-090BAS24 A MDS-150AAS12 B MDS-150AAS19 F/B MDS-150AAS24 F/B MDS-150CAB19 A
Output Voltage 24V 12V 19V 24V 19V
Output Power 90W 120W 150W 150W
150W
Output Current 3.75A 10A 7.89A 6.25A
7.9A
Input Voltage Range 90-264Vac 90-264Vac 90-264Vac 90-264Vac 90-264Vac
Dimensions (L x W x D) 150 x 75 x 40 mm
5.91” x 2.95” x 1.57”
170 x 85 x 40 mm
6.69” x 3.35” x 1.57”
170 x 85 x 40 mm
6.69” x 3.35” x 1.57”
170 x 85 x 40 mm
6.69” x 3.35” x 1.57”
150.0 x 65.0 x 32.0 mm
5.91” x 2.56” x 1.26”
Highlights & Features  -Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 62368-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Low touch current (<0.1mA Normal & ,0.3mA single fault)
-Over-Voltage/Load/Temperature & Short Circuit protections
-1 Million Hours MTBF
-2 × MOPP isolation
-3 years warranty
 -Meet DOE Level VI and ErP Lot 7
-Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 62368-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Low touch current (<0.1 mA Normal & <0.3 mA single fault)
-Over-Voltage/Load/Temperature & Short Circuit protections
-1 Million Hours MTBF
-2 × MOPP isolation
-3 years warranty
 -Meet Efficiency Level VI
-Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 62368-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Low touch current (<0.1 mA Normal & <0.3 mA single fault)
-Over-Voltage/Load/Temperature & Short Circuit protections
-1 Million Hours MTBF
-2 × MOPP isolation
-3 years warranty
 -Meet DOE Level VI and ErP Lot 7
-Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 62368-1
-Compliant with IEC 60601-1-2 4th Ed. Requirements
-Low touch current (<0.1 mA Normal & <0.3 mA single fault)
-Over-Voltage/Load/Temperature & Short Circuit protections
-1 Million Hours MTBF
-2 × MOPP isolation
 -Safety Approvals to IEC 60601-1 3rd ed. & IEC 62368-1
-Risk management report available
-Low touch current (<0.1 mA Normal & <0.3 mA single fault)
-Over-Voltage/Load/Temperature & Short Circuit protections
-2.1 Million Hours MTBF
-2 x MOPP (means of patient protection)
-3 years warranty

Contact us for more information