Alimentation industrielle CHROME Delta


Description

DRC-12V100W1AZ DRC-12V10W1AZ DRC-12V30W1AZ DRC-12V60W1AZ DRC-24V100W1AZ
Output Voltage 12V 12V 12V 12V 24V
Output Power 72W 9.96W 25W 54W 91.2W
Output Current 6A 0.83A 2.1A 4.5A 3.8A
Input Voltage Range 90-264Vac 90-264Vac 90-264Vac 90-264Vac 90-264Vac
Dimensions (L x W x D) 91 x 89.9 x 55.6 mm
3.58” x 3.54” x 2.19”
91 x 18 x 55.6 mm
3.58” x 0.71” x 2.19”
91 x 53 x 55.6 mm
3.58” x 2.09” x 2.19”
91 x 71 x 55.6 mm
3.58” x 2.80” x 2.19”
91 x 89.9 x 55.6 mm
3.58” x 3.54” x 2.19”
Highlights & Features -Class, Double Isolation (No Earth connection is required)
-Universal AC input voltage range and full power up to 55°C
-Power will not de-rate for the entire input voltage range
-Efficiency > 86.0% @ 115Vac & 230Vac
-Can be installed in compact cabinets
-Low earth leakage current < 0.25mA @ 264Vac
-Conforms to harmonic current IEC/EN 61000-3-2, Class A
-A1Safety approval according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1 and UL508
-Class II, Double Isolation (No Earth connection is required)
-Universal AC input voltage range and full power up to 55°C
-Power will not de-rate for the entire input voltage range
-Efficiency > 82.0% @ 115Vac & 230Vac
-Can be installed in compact cabinets
-NEC Class 2 and Limited Power Source (LPS) approvals
-Conforms to harmonic current IEC/EN 61000-3-2, Class A
-Safety approval according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1 and UL508
-Class II, Double Isolation (No Earth connection is required)
-Universal AC input voltage range and full power up to 55°C
-Power will not de-rate for the entire input voltage range
-Efficiency > 85.0% @ 115Vac & 230Vac
-Can be installed in compact cabinets
-NEC Class 2 and Limited Power Source (LPS) approvals
-Conforms to harmonic current IEC/EN 61000-3-2, Class A
-Safety approval according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1 and UL508
-Class II, Double Isolation (No Earth connection is required)
-Universal AC input voltage range
-Power will not de-rate for the entire input voltage range
-Efficiency > 86.0% @ 115Vac & 230Vac
-Can be installed in compact cabinets
-NEC Class 2 and Limited Power Source (LPS) approvals for selected models
-Conforms to harmonic current IEC/EN 61000-3-2, Class A
-Safety approval according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1 and UL508 for selected models
-Class II Double Isolation (No Earth connection is required)
-Universal AC input voltage range and full power up to 55°C
-Power will not de-rate for the entire input voltage range
-Efficiency > 89.0% @ 230 Vac
-Can be installed in compact cabinets
-NEC Class 2 and Limited Power Source (LPS) approvals
-Conforms to harmonic current IEC/EN 61000-3-2, Class A
-Safety approval according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1 and UL508
DRC-24V10W1AZ DRC-24V10W1HZ DRC-24V30W1AZ DRC-24V60W1AZ DRC-5V10W1AZ
Output Voltage 24V 24V 24V 24V 5V
Output Power 10W 10W 30W 60W 7.5W
Output Current 0.42A 0.42A 1.25A 2.5A 1.5A
Input Voltage Range 90-264Vac 90-264Vac 90-264Vac 90-264Vac 90-264Vac
Dimensions (L x W x D) 91 x 18 x 55.6 mm
3.58” x 0.71” x 2.19”
91 x 18 x 55.6 mm
3.58” x 0.71” x 2.19”
91 x 53 x 55.6 mm
3.58” x 2.09” x 2.19”
91 x 71 x 55.6 mm
3.58” x 2.80” x 2.19”
91 x 18 x 55.6 mm
3.58” x 0.71” x 2.19”
Highlights & Features -Class II, Double Isolation (No Earth connection is required)
-Universal AC input voltage range and full power up to 55°C
-Power will not de-rate for the entire input voltage range
-Efficiency > 80.0% @ 115Vac & 230Vac
-Can be installed in compact cabinets
-NEC Class 2 and Limited Power Source (LPS) approvals
-Conforms to harmonic current IEC/EN 61000-3-2, Class A
-Safety approval according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1 and UL508
-Class II, Double Isolation (No Earth connection is required)
-Household appliance approvals IEC/EN 60335-1
-Universal AC input voltage range and full power up to 55°C
-Power will not de-rate for the entire input voltage range
-Can be installed in compact cabinets
-Efficiency > 80.0% @ 115Vac & 230Vac
-NEC Class 2 and Limited Power Source (LPS) approvals
-Conforms to harmonic current IEC/EN 61000-3-2, Class A
-Safety approval according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1
-Class II, Double Isolation (No Earth connection is required)
-Universal AC input voltage range and full power up to 55°C
-Power will not de-rate for the entire input voltage range
-Efficiency > 87.0% @ 115Vac & 230Vac
-Can be installed in compact cabinets
-NEC Class 2 and Limited Power Source (LPS) approvals
-Conforms to harmonic current IEC/EN 61000-3-2, Class A
-Safety approval according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1 and UL508
-Class II, Double Isolation (No Earth connection is required)
-Universal AC input voltage range and full power up to 55°C
-Power will not de-rate for the entire input voltage range
-Efficiency > 88.0% @ 115Vac & 230Vac
-Can be installed in compact cabinets
-NEC Class 2 and Limited Power Source (LPS) approvals
-Conforms to harmonic current IEC/EN 61000-3-2, Class A
-Safety approval according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1 and UL508
-Class II, Double Isolation (No Earth connection is required)
-Universal AC input voltage range and full power up to 55°C
-Power will not de-rate for the entire input voltage range
-Efficiency > 77.0% @ 115Vac & 230Vac
-Can be installed in compact cabinets
-NEC Class 2 and Limited Power Source (LPS) approvals
-Conforms to harmonic current IEC/EN 61000-3-2, Class A
-Safety approval according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1 and UL508

Contactez-nous pour toute information

Vous pourriez également être intéressé par...