Alimentation industrielle SYNC Delta


Description

DRS-12V50W1NZ DRS-24V100W1AZ DRS-24V100W1NZ DRS-24V30W1AZ DRS-24V30W1NZ DRS-24V50W1NZ DRS-5V30W1NZ DRS-5V50W1AZ DRS-5V50W1NZ
Output Voltage 12V 24V 24V 24V 24V 24V 5V 5V 5V
Output Power 48W 96W 91W 30W 30W 50W 15W 30W 25W
Output Current 4A 4A 3.8A 1.25A 1.25A 2.1A 3A 6A 5A
Input Voltage Range 85-264Vac 85-264Vac 85-264Vac 85-264Vac 85-264Vac 85-264Vac 85-264Vac 85-264Vac 85-264Vac
Dimensions (L x W x D) 75 x 30 x 89.5 mm
2.95” x 1.18” x 3.52”
75 x 45 x 100 mm
2.95” x 1.77” x 3.94”
75 x 45 x 100 mm
2.95” x 1.77” x 3.94”
75 x 21 x 89.5 mm
2.95” x 0.83” x 3.52”
75 x 21 x 89.5 mm
2.95” x 0.83” x 3.52”
75 x 30 x 89.5 mm
2.95” x 1.18” x 3.52”
75 x 21 x 89.5 mm
2.95” x 0.83” x 3.52”
75 x 30 x 89.5 mm
2.95” x 1.18” x 3.52”
75 x 30 x 89.5 mm
2.95” x 1.18” x 3.52”
Highlights & Features -Ultra-compact size and galvanic isolation up to 3.0KVac between input to output and input to ground
-Universal AC input voltage and full power from -10°C to +55°C operation
-Up to 89.0% efficiency
-Low earth leakage current < 0.5mA @ 264Vac
-Built-in DC OK relay contact option available
-Extreme low temperature cold start at -40°C
-NEC Class 2 / Limited Power Source (LPS) certified
-Certified according to IEC/EN/UL 62368-1
-Ultra-compact size and galvanic isolation up to 3.0KVac between input to output and input to ground
-Universal AC input voltage and full power from -10°C to +55°C operation
-Up to 89.0% efficiency and built-in active PFC
-Low earth leakage current < 0.5mA @ 264Vac
-Built-in DC OK relay contact option available
-Extreme low temperature cold start at -40°C
-Certified according to IEC/EN/UL 62368-1
-Ultra-compact size and galvanic isolation up to 3.0KVac between input to output and input to ground
-Universal AC input voltage and full power from -10°C to +55°C operation
-Up to 89.0% efficiency and built-in active PFC
-Low earth leakage current < 0.5mA @ 264Vac
-Built-in DC OK relay contact option available
-Extreme low temperature cold start at -40°C
-NEC Class 2 / Limited Power Source (LPS) certified (DRS-24V100W1N☐)
-Certified according to IEC/EN/UL 62368-1
-Ultra compact size and galvanic isolation up to 3.0KVac between input to output
-Universal AC input voltage and full power from -10°C to +55°C operation
-Up to 88.0% efficiency
-Low earth leakage current < 0.5mA @ 240Vac
-NEC Class 2 / Limited Power Source (LPS) certified
-Overvoltage / Overcurrent / Over Temperature Protections
-Meet Surge Immunity IEC 61000-4-5, Level 4 (CM: 4kV, DM: 2kV)
"-Ultra compact size and galvanic isolation up to 3.0KVac between input to output and input to ground
-Universal AC input voltage and full power from -10°C to +55°C operation
-Up to 88.0% efficiency
-Low earth leakage current < 1.0mA @ 264Vac
-Extreme low temperature cold start at -40°C
-NEC Class 2 / Limited Power Source (LPS) certified
-Overvoltage / Overcurrent / Over Temperature Protections
-Certified according to IEC/EN/UL 62368-1
-Ultra-compact size and galvanic isolation up to 3.0KVac between input to output and input to ground
-Universal AC input voltage and full power from -10°C to +55°C operation
-Up to 90.0% efficiency
-Low earth leakage current < 0.5mA @ 264Vac
-Built-in DC OK relay contact option available
-Extreme low temperature cold start at -40°C
-NEC Class 2 / Limited Power Source (LPS) certified
-Certified according to IEC/EN/UL 62368-1
-Ultra compact size
-Full power from -10°C to +55°C operation
-Universal AC input voltage
-Up to 79.0% efficiency
-Extreme low temperature cold start at -40°C
-NEC Class 2 / Limited Power Source (LPS) certified
-Overvoltage / Overcurrent / Over Temperature Protections
-Certified according to IEC/EN/UL 62368-1
-Ultra-compact size and galvanic isolation up to 3.0KVac between input to output and input to ground
-Universal AC input voltage and full power from -10°C to +55°C operation
-Up to 82.0% efficiency
-Low earth leakage current < 0.75mA @ 264Vac
-Built-in DC OK relay contact option available
-Extreme low temperature cold start at -40°C
-Certified according to IEC/EN/UL 62368-1
-Ultra-compact size and galvanic isolation up to 3.0KVac between input to output and input to ground
-Universal AC input voltage and full power from -10°C to +55°C operation
-Up to 82.0% efficiency
-Low earth leakage current < 0.75mA @ 264Vac
-Built-in DC OK relay contact option available
-Extreme low temperature cold start at -40°C
-NEC Class 2 / Limited Power Source (LPS) certified (DRS-5V50W1N☐)
-Certified according to IEC/EN/UL 62368-1

Contact us for more information